- 195 -
Function
code
Name
LED
display
Setup range
Minimu
m unit
Factor
y
default
value
Modifi
c-ation
descri
p-tion
U0-09
AI1
voltage(afte
r corrected)
AI1
voltage(afte
r corrected)
-10.00V10.000V
U0-10
AI2
voltage(afte
r corrected)
AI2
voltage(afte
r corrected)
-10.00V10.000V
U0-11
AI3voltage(
after
corrected)
AI3voltage(
after
corrected)
-10.00V10.000V
U0-12
U0-29
Reserved
U0-30
AI1
voltage(befo
re
corrected)
AI1
voltage(bef
ore
corrected)
-10.00V10.000V
U0-31
AI2voltage(
before
corrected)
AI2
voltage(bef
ore
corrected)
-10.00V10.000V
U0-32
AI3
voltage(befo
re
corrected)
AI3
voltage(bef
ore
corrected)
-10.00V10.000V
Group A0 Weak magnetism and SVC control group
A0-00
Weak
magnetism
control
mode
Weak
magnetism
control
mode
0:Direct
calculation
1:Automatic
adjustment
1 0
A0-01
Weak
magnetismc
urrent
coefficient
Weak
magnetism
current
coefficient
80%200%
1 100%