- 199 -
Function
code
Name
LED
display
Setup range
Minimu
m unit
Factor
y
default
value
Modifi
c-ation
descri
p-tion
F2-10
Torque
upper limit
Torque
upper limit
0.0%250.0%
0.1% 200.0%
F2-13
D axis
current loop
Kp
D axis
current loop
Kp
065535
1 50
F2-14
D axis
current loop
Ki
D axis
current loop
Ki
065535
1 50
F2-15
Q axis
current loop
Kp
Q axis
current loop
Kp
065535
1 50
F2-16
Q axis
current loop
Ki
Q axis
current loop
Ki
065535
1 50
Group F4 Input terminal
F4-32
AI3 input
filter time
AI3 filter
time
0.00s10.00s
0.01s 0.00s
Group F7 Keyboard and Display
F7-10
Software
version
No.1
Software
version No.1
- - -
F7-11
Software
version
No.2
Software
version No.2
- - -
Group FP User Password
FP-00
user
password1
Authorizatio
n for all
functions
code except
FP-05
065535
1 0