- 111 -
Function
Code
Name LED Display Setting Range Min. Unit Default Property
F0-02
Command source
selection
Command source
selection
0: Operation panel (LED
OFF)
1: Terminal (LED ON)
2: Communication setting
(LED blinking)
1 0
☆
F0-03 Main frequency source
X selection
Main frequency source
X selection
0: Digital setting (UP/DOWN
modication, non-retentive)
1: Digital setting (UP/DOWN
modication, retentive)
2: AI1
3: AI2
4: AI3
5: Reserved
6: Multi-speed
7: Reserved
8: Reserved
9: Communication setting
1 1
★
F0-04 to
F0-07
Reserved - - - -
☆
F0-08 Preset frequency Preset frequency 0.00 Hz to max. frequency
(F0-10)
0.01 Hz 50.00 Hz
☆
F0-09 Rotating direction Rotating direction 0: Same direction
1: Reverse direction
1 0
☆
F0-10 Max. frequency Max. frequency 50.00 to 300.00 Hz 1 200.00 Hz
★
F0-11 Source of frequency
upper limit
Source of frequency
upper limit
0: Set by F0-12
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication setting
1 0
★
F0-12 Frequency upper limit Frequency upper limit Frequency lower limit (F0-
14) to max. frequency (F0-
10)
0.01 Hz 200.00 Hz
☆
F0-13 Upper limit offset Upper limit offset 0.00 Hz to maximum
frequency (F0-10)
0.01 Hz 0.00 Hz
☆
F0-14 Frequency lower limit Frequency lower limit 0.00 Hz to frequency upper
limit (F0-12)
0.01 Hz 0.00 Hz
☆
F0-15 Carrier frequency Carrier frequency 0.5 to 8.0 kHz 0.1 kHz Model
dependent
☆
F0-16 Carrier frequency
adjustment selection
Carrier frequency
adjustment selection
☆