- 112 -
Function
Code
Name LED Display Setting Range Min. Unit Default Property
F0-17
Acceleration time 1 Acceleration time 1 0.0s to 6500.0s 0.1s 20.0s
☆
F0-18 Deceleration time 1 Deceleration time 1 0.0s to 6500.0s 0.1s 20.0s
☆
Group F1: Motor Parameters
F1-00 Motor type selection Motor type selection 0: Common asynchronous
motor
1: Variable frequency
asynchronous motor
2: PMSM
1 2
★
F1-01 Rated motor power Rated motor power 0.4 to 1000.0 kW 0.1 kW Model
dependent
★
F1-02 Rated motor voltage Rated motor voltage 0 to 480 V 1 V Model
dependent
★
F1-03 Rated motor current Rated motor current 0.01 to 650.00 A 0.01 A Model
dependent
★
F1-04 Rated motor frequency Rated motor frequency 0.00 Hz to max. frequency
(F0-10)
0.01 Hz Model
dependent
★
F1-05 Rated motor speed Rated motor speed 0 to 30000 rpm 1 rpm Model
dependent
★
F1-06 to
F1-10
Reserved - - - -
☆
F1-11 Shaft D inductance Shaft D inductance 0–65535 1 Model
dependent
★
F1-12 Shaft Q inductance Shaft Q inductance 0–65535 1 Model
dependent
★
F1-13 Stator resistance Stator resistance 0–65535 1 Model
dependent
★
F1-14 Unit Unit 0–65535 1 Model
dependent
★
F1-15 Back EMF Back EMF 0–65535 V 1 Model
dependent
★