MD021 Plastic Wire Drawing Machine User Manual
This parameter needs to be set when F2-00 is set to 0. This parameter
is set on the operation panel.
The base value of this parameter is the feedback value of the system.
PID setting and
feedback range
This parameter is a non-dimensional unit, and is used for PID setting
display and PID feedback display.
For example, when this parameter is set to 1000, 0% to 100% of the
PID setting value corresponds to 0 to 1000 in a linear mode.
Proportional gain P: It decides the regulating intensity of the PID
regulator. The larger P is, the greater the regulating intensity is. If it is