4 Quick Setup
- 25 -
F4-00 DI1 function selection 1
30: Pulse input as frequency reference (valid only for DI4)
32: Immediate DC injection braking
33: External fault normally-closed input
34: Frequency modication enabled
35: PID operation direction reverse
36: External stop 1
37: Command source switchover 2
38: PID integral disabled
39: Switchover between main frequency reference and preset frequency
40: Switchover between auxiliary frequency reference and preset frequency
43: PID parameter switchover
47: Emergency stop (ES)
48: External stop 2
49: Deceleration DC injection braking
50: Clear running time this time
51: Two-wire control/ Three-wire control
52: Reverse running prohibited
F4-01 DI2 function selection 4
Setting range same as DI1.
F4-02 DI3 function selection 9
Setting range same as DI1.
F4-03 DI4 function selection 12
If any digital output is used Setting range same as DI1.
Set the DO function
.
F5-02 Relay function selection(T/A-T/C) 2
0: No output
1: AC drive running
2: Fault output
3: Frequency level detection 1 output
4: Frequency reached
5: Zero-speed running (no output at stop)
6: Motor overload pending
7: AC drive overload pending
11: PLC cycle completed
12: Accumulative running time reached
13: Frequency limited
15: Ready for RUN
17: Frequency upper limit reached
18: Frequency lower limit reached (no output at stop)
19: Undervoltage
20: Communication setting
24: Accumulative power-on time reached
26: Frequency 1 reached
28: Current 1 reached
30: Timing reached
CONTINUE Para. Parameter Name Default Commission