Parameter Description MD280/MD280N User Manual
- 140 -
Setup
value
Function Description
counting pulse
value arrival
F7-05, it outputs ON signal. Refer to F7-08 and
F7-09 function codes for the description of length
counting function.
12 Length arrival
When the actual length exceeds the setup value in
F7-05, it outputs ON signal. Refer to F7-08 and
F7-09 function codes for the description of length
counting function.
13
PLC circulation
end
When the simple PLC running finishes one
circulation, it output a pulse signal with width of
250ms.
14 Run time reached
When the accumulated running time (F7-12) of the
inverter exceeds the setup time (F5-12), it outputs
ON signal. Refer to F5-12 and F5-13 function codes
for the description of timing function.
15
Communication
control
It is controlled by the host computer. Refer to MD280
Series Communication Protocol for details.
16 RUN ready
When the inverter has no fault and the bus voltage
works normally and the inverter is ready for running,
it outputs ON signal. Upon normal startup, it closes
the output.
17 AI1>AI2
When the voltage value of analog input AI1 is higher
than that of analog input AI2, it output ON signal.
18
Zero-current is
detected
When the zero-current is detected, it output ON
signal.
19
External brake
signal
Refer to F5-39 and F5-40.
20
Software
over-curent DO
output
Refer to F5-27.
F3-05
FMP and AO
output selection
Factory
default
value
0
The standard output (zero offset is 0 and gain is 1) of the analog output is 0
to 20mA (or 0V to 10V, and the FMP output range is between 0Hz and
setup value of function code F3-08.
The corresponding value range is as shown in the table below: