Function Parameter Table MD280/MD280N User Manual
- 88 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
F5-21 Wake-u
p
frequenc
y
Wake-up frequency to maximum
frequency˄F0-04)
0.01Hz 0.00Hz ƿ
F5-22 Wake-u
p delay
time
0.0s to 6500.0s 0.1s 0.0s ƿ
F5-23
Sleep
frequenc
y
0.00Hz to maximum frequency
˄F0-04)
0.01Hz 0.00Hz ƿ
F5-24
Sleep
delay
time
0.0s to 6500.0s 0.1s 0.0s ƿ
F5-25 Software
over-cur
rent
points
0.0% to 300.0% ˄ motor rated
current˅
0.1% 200.0% ƿ
F5-26 Software
over-cur
rent
detectio
n delay
time
0.00s˄not detection˅
0.01s to 600.00s
0.01s 0.00s ƿ
F5-37 Dead-zo
ne
compen
sation
mode
selection
0 to 1 1 0 ƾ
F5-38
Cooling
fan
0:Cooling fan startup of motor
running
1 0 ƿ