MD280/MD280N User Manual Function Parameter Table
- 85 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
frequenc
y
F5-01
Jog
speed-u
p time
0.00s to 300.00s 0.01s 20.00s ƿ
F5-02
Jog
speed-d
own time
0.00s to 300.00s 0.01s 20.00s ƿ
F5-03
Jog
enabled
during
operatio
n
0: Disabled
1: Enable
1 0 ƿ
F5-04
Speed-u
p time 2
0.00s(m) to 300.00s(m)
0.01s(m
)
Model
dependent
ƿ
F5-05
Speed-d
own time
2
0.00s(m) to 300.00s(m)
0.01s(m
)
Model
dependent
ƿ
F5-06
Skip
frequenc
y
0.00Hz to maximum frequency
(F0-04)
0.01Hz 0.00Hz ƿ
F5-07
Skip
frequenc
y
amplitud
e
0.00Hz to maximum frequency
(F0-04)
0.01Hz 0.00Hz ƿ
F5-08
Dead
zone
time of
Forward
and
0.0s to 100.0s 0.1s 0.0s ƿ
efesotomasyon.com