22
F0-15 Start mode
0: Direct start
1: Rotation velocity search restart
1 0 × 15
F0-16 Stop mode
0: Deceleration stop
1: Coast to stop
1 0 16
F1 Motor Parameter
F1-00 Motor type selection
0: Common asynchronous motor
1: variable frequency asynchronous motor
2: Permanent magnetic synchronous
motor (Reserved)
1 0 × 17
F1-01 Rated power 0.1kW ~ 1000.0kW 0.1
Depending
on inverter
model
× 18
F1-02 Rated voltage 0V ~ 440V 1
Depending
on inverter
model
× 19
F1-03 Rated current 0.00A ~ 655.00A 0.01
Depending
on inverter
model
× 20
F1-04 Rated frequency 0.0Hz ~ 3200.0Hz 1 50.0Hz × 21
F1-05 Rated speed 0rpm ~ 30000rpm 1 1460 × 22
F1-06 Stator resistance 0.001 ~ 65.535 0.001
Depending
on inverter
model
23
F1-07 Rotor resistance 0.001 ~ 65.535 0.001
Depending
on inverter
model
24
F1-08 Leakage inductance 0.01 ~ 655.35mH 0.01mH
Depending
on inverter
model
25
F1-09 Mutual inductance 0.1mH ~ 6553.5mH 0.1mH
Depending
on inverter
model
26
F1-10 Excitation current 0.01A ~ 655.35A 0.01A
Depending
on inverter
model
27
F1-11 Tuning selection
0: No tuning
1: Static tuning
2: Complete tuning
1 0 × 28
F2 Vector and VF Control Parameter