MD380 User Manual Desc
ription of Function Codes
- 137 -
)unction Code Parameter Name Setting Range Default
)0-02
Command
source selection
0: Operation panel control (LED off
)
1: Te
rminal control (LED on)
2: Communication control (LED blinking)
0
It is used to determine the input channel of the AC drive control commands, such as run,
stop, forward rotation, reverse rotation and jog operation. You can input the commands in
the following three channels:
 0: Operation panel control ("LOCAL/REMOT" indicator off)
Commands are given by pressing keys
RUN
and
STOP
RES
on the operation panel.
 1: Terminal control ("LOCAL/REMOT" indicator on)
Commands are given by means of multifunctional input terminals with functions such
DV):'5(9-2*)DQG-2*5
 2: Communication control ("LOCAL/REMOT" indicator blinking)
Commands are given from host computer. If this parameter is set to 2, a communication
FDUG0RGEXV578352),%86'3FDUG&$1OLQNFDUGXVHUSURJUDPPDEOHFDUGRU
CANopen card) must be installed.
,ID352),%86'3FDUGLVVHOHFWHGDQG3='GDWDLVYDOLGFRPPDQGVDUHJLYHQ
E\PHDQVRI3='GDWD
If a user programmable card is selected, commands are written to A7-08 by
means of the programmable card.
If any other card is selected, commands are written by means of the
communication address 0x2000.
)unction Code Parameter Name Setting Range Default
)0-03
Main frequency
source X selection
0: Digital setting (non-retentive at power
failure)
1: Digital setting (retentive at power failure)
2: A
I1
3: AI2
4: A
I3
5: Pulse setting (DI5)
6: Multi-reference
7: Simple PLC
8: PID
9: Communication setting
0