Description of Function Codes
MD380 User Manual
- 170 -
)unction Code Parameter Name Setting Range Default
)4-28 Pulse minimum input 0.00 kHz to )4-30 0.00 kHz
)4-29
Corresponding setting of
pulse minimum input
-100.00%–100.0% 0.0%
)4-30 Pulse maximum input )4-28 to 50.00 kHz 50.00 kHz
)4-31
Corresponding setting of
pulse maximum input
-100.00%–100.0% 100.0%
)4-32 Pulse ¿lter time 0.00–10.00s 0.10s
These parameters are used to set the relationship between DI5 pulse input and
corresponding settings. The pulses can only be input by DI5. The method of setting this
function is similar to that of setting AI1 function.
)unction Code Parameter Name Setting Range Default
)4-33 AI curve selection
Unit's digit (AI1 curve selection)
321
Curve 1 (2 points, see )4-13 to )4-16)
Curve 2 (2 points, see )4-18 to )4-21)
Curve 3 (2 points, see )4-23 to )4-26)
Curve 4 (4 points, see A
6-00 to A6-07)
Curve 5 (4 points, see A
6-08 to A6-15)
Ten's digit (AI2 curve selection)
Curve 1 to curve 5 (same as A
I1)
Hundred's digit (AI3 curve selection)
Curve 1 to curve 5 (same as A
I1)
The unit's digit, ten's digit and hundred's digit of this parameter are respectively used to
VHOHFWWKHFRUUHVSRQGLQJFXUYHRI$,$,DQG$,$Q\RIWKH¿YHFXUYHVFDQEHVHOHFWHG
for AI1, AI2 and AI3.
&XUYHFXUYHDQGFXUYHDUHDOOSRLQWFXUYHVVHWLQJURXS)&XUYHDQGFXUYH
are both 4-point curves, set in group A6.
The MD380 provides two AI terminals as standard. AI3 is provided by an optional extension
card.
)unction Code Parameter Name Setting Range Default
)4-34
Setting for A
I less
than minimum input
Unit's digit (Setting for A
I1 less than
minimum input)
000
0: Minimum value
1: 0.0%
Te
n's digit (Setting for AI2 less than
minimum input)
0, 1 (same as A
I1)
Hundred's digit (Setting for A
I3 less
than minimum input)
0, 1 (same as AI1)