MD380 User Manual Desc
ription of Function Codes
- 175 -
)unction Code Parameter Name Default
)5-06 )MP
function selection
0
)5-07 AO1 function selection
0
)5-08 AO2 function selection
1
7KHRXWSXWSXOVHIUHTXHQF\RIWKH)03WHUPLQDOUDQJHVIURPN+]WR0D[LPXP)03
RXWSXWIUHTXHQF\)7KHYDOXHRI)LVEHWZHHQN+]DQGN+]
The output range of AO1 and AO2 is 0–10 V or 0–20 mA. The relationship between pulse
and analog output ranges and corresponding functions is listed in the following table.
Table 6-6 Relationship between pulse and analog output ranges and corresponding
functions
Value )unction
Range (Corresponding to Pulse or Analog
Output Range 0.0%–100.0%)
0 Running frequency 0 to maximum output frequency
1 Set frequency 0 to maximum output frequency
2 Output current 0 to 2 times of rated motor current
3 Output torque (absolute value) 0 to 2 times of rated motor torque
4 Output power 0 to 2 times of rated power
5 Output voltage 0 to 1.2 times of rated A
C drive voltage
6 Pulse input 0.01–100.00 kHz
7 AI1 0–10 V
8 AI2 0–10 V (or 0–20 mA)
9 AI3 0–0 V
10 Length 0 to maximum set length
11 Count value 0 to maximum count value
12 Communication setting 0.0%–100.0%
13 Motor rotational speed
0 to rotational speed corresponding to
maximum output frequency
14 Output current 0.0–1000.0 A
15 Output voltage 0.0–000.0 V
16 Output torque (actual value)
-2 times of rated motor torque to 2 times of
rated motor torque
)unction Code Parameter Name Setting Range Default
)5-09 Maximum )MP output frequency 0.01–100.00 kHz 50.00 kHz
,IWKH)0WHUPLQDOLVXVHGIRUSXOVHRXWSXWWKLVSDUDPHWHULVXVHGWRVHWWKHPD[LPXP
frequency of pulse output.