MD380 User Manual Desc
ription of Function Codes
- 179 -
)unction Code Parameter Name Setting Range Default
)6-05 Startup DC braking current/Pre-excited current 0%–100% 0%
)6-06 Startup DC braking time/Pre-excited time 0.0–100.0s 0.0s
Startup DC braking is generally used during restart of the AC drive after the rotating motor
VWRSV3UHH[FLWDWLRQLVXVHGWRPDNHWKH$&GULYHEXLOGPDJQHWLF¿HOGIRUWKHDV\QFKURQRXV
motor before startup to improve the responsiveness.
6WDUWXS'&EUDNLQJLVYDOLGRQO\IRUGLUHFWVWDUW),QWKLVFDVHWKH$&GULYH
performs DC braking at the set startup DC braking current. After the startup DC braking
time, the AC drive starts to run. If the startup DC braking time is 0, the AC drive starts
directly without DC braking. The larger the startup DC braking current is, the larger the
braking force is.
,IWKHVWDUWXSPRGHLVSUHH[FLWHGVWDUW) WKH$&GULYHEXLOGVPDJQHWLF¿HOGEDVHG
on the set pre-excited current. After the pre-excited time, the AC drive starts to run. If the
pre-excited time is 0, the AC drive starts directly without pre-excitation.
The startup DC braking current or pre-excited current is a percentage relative to the base
value.
 If the rated motor current is less than or equal to 80% of the rated AC drive current, the
base value is the rated motor current.
 If the rated motor current is greater than 80% of the rated AC drive current, the base
value is 80% of the rated AC drive current.
)unction Code Parameter Name Setting Range Default
)6-07
Acceleration/
Deceleration mode
0: Linear acceleration/deceleration
1: S-curve acceleration/deceleration A
2: S-curve acceleration/deceleration %
0
It is used to set the frequency change mode during the AC drive start and stop process.
 0: Linear acceleration/deceleration
The output frequency increases or decreases in linear mode. The MD380 provides four
JURXSRIDFFHOHUDWLRQGHFHOHUDWLRQWLPHZKLFKFDQEHVHOHFWHGE\XVLQJ)WR)
 1: S-curve acceleration/deceleration A
The output frequency increases or decreases along the S curve. This mode is generally
used in the applications where start and stop processes are relatively smooth, such as
HOHYDWRUDQGFRQYH\RUEHOW)DQG)UHVSHFWLYHO\GH¿QHWKHWLPHSURSRUWLRQVRI
the start segment and the end segment.
 6FXUYHDFFHOHUDWLRQGHFHOHUDWLRQ%
In this curve, the rated motor frequency
b
f
LVDOZD\VWKHLQÀH[LRQSRLQW7KLVPRGHLV
usually used in applications where acceleration/deceleration is required at the speed
higher than the rated frequency.