MD380 User Manual Desc
ription of Function Codes
- 197 -
)unction Code Parameter Name Setting Range Default
)8-48 Cooling fan control
0: )an working during running
1: )an working continuously
0
It is used to set the working mode of the cooling fan. If this parameter is set to 0, the fan
works when the AC drive is in running state. When the AC drive stops, the cooling fan
works if the heatsink temperature is higher than 40°C, and stops working if the heatsink
temperature is lower than 40°C.
If this parameter is set to 1, the cooling fan keeps working after power-on.
)unction Code Parameter Name Setting Range Default
)8-49 Wa
keup frequency
Dormant frequency ()8-51) to
maximum frequency ()0-10)
0.00 Hz
)8-50 Wa
keup delay time 0.0–6500.0s 0.0s
)8-51 Dormant frequency 0.00 Hz to wakeup frequency ()8-49) 0.00 Hz
)8-52 Dormant delay time 0.0–6500.0s 0.0s
These parameters are used to implement the dormant and wakeup functions in the water
supply application.
When the AC drive is in running state, the AC drive enters the dormant state and stops
DXWRPDWLFDOO\DIWHUWKHGRUPDQWGHOD\WLPH)LIWKHVHWIUHTXHQF\LVORZHUWKDQRUHTXDO
WRWKHGRUPDQWIUHTXHQF\)
When the AC drive is in dormant state and the current running command is effective, the AC
GULYHVVWDUWVXSDIWHUWKHZDNHXSGHOD\WLPH)LIWKHVHWIUHTXHQF\ LV KLJKHU WKDQ RU
HTXDOWRWKHZDNHXSIUHTXHQF\)
Generally, set the wakeup frequency equal to or higher than the dormant frequency. If the
wakeup frequency and dormant frequency are set to 0, the dormant and wakeup functions
are disabled.
When the dormant function is enabled, if the frequency source is PID, whether PID
RSHUDWLRQLVSHUIRUPHGLQWKHGRUPDQWVWDWHLVGHWHUPLQHGE\)$,QWKLVFDVHVHOHFW3,'
RSHUDWLRQHQDEOHGLQWKHVWRSVWDWH)$
)unction Code Parameter Name Setting Range Default
)8-53 Current running time reached 0.0–6500.0 min 0.0 min
If the current running time reaches the value set in this parameter, the corresponding DO
becomes ON, indicating that the current running time is reached.
)unction Code Parameter Name Setting Range Default
)8-54 Output power correction coef¿cient 0.00%–200 .0% 100.0%
When the output power (U0-05) is not equal to the required value, you can perform linear
correction on output power by using this parameter.