MD380 User Manual EMC
- 253 -
AC Drive Model
Rated Input Current
(A)
AC Input Reactor Model
(Inovance)
MD380-5T90G 180 MD-ACL-200-4T-753-2%
MD380-5T11
0G 214 MD-ACL-250-4T-114-2%
MD380-5T132G 256 MD-ACL-330-4T-
164-2%
MD380-5T160G 307 MD-ACL-330-4T-
164-2%
MD380-5T200G 385 MD-ACL-490-4T-
224-2%
MD380-5T220G 430 MD-ACL-490-4T-
224-2%
MD380-5T250G 468 MD-ACL-490-4T-
224-2%
MD380-5T280G 525 MD-ACL-660-4T-
304-2%
MD380-5T315G 590 MD-ACL-660-4T-
304-2%
MD380-5T355G 665 MD-ACL-800-4T-
384-2%
MD380-5T400G 785 MD-ACL-800-4T-
384-2%
Three-phase power: 690 V,
50/60 Hz
MD380-7T55G 70 ACL-0080-EISC-EM19%
MD380-7T75G 90 ACL-0090-EISC-EM19%
MD380-7T90G 105 ACL-0120-EISH-EM13%
MD380-7T11
0G 130 ACL-0120-EISH-EM13%
MD380-7T132G 170 ACL-0150-EISH-EM11
%
MD380-7T160G 200 ACL-0200-EISH-E80U%
MD380-7T200G 235 ACL-0250-EISH-E65U%
MD380-7T220G 247 ACL-0250-EISH-E65U%
MD380-7T250G 265 ACL-0290-EISH-E50U%
MD380-7T280G 305 ACL-0330-EISH-E50U%
MD380-7T315G 350 ACL-0330-EISH-E50U%
MD380-7T355G 382 ACL-0390-EISH-E44U%
MD380-7T400G 435 ACL-0490-EISH-E35U%
MD380-7T450G 490 ACL-0490-EISH-E35U%
MD380-7T500G 595 ACL-0600-EISH-E25U%
7.3.3 Installation of AC Output Reactor on Power Output Side
Whether to install an AC output reactor on the power output side is dependent on the
actual situation. The cable connecting the AC drive and the motor should not be too long;
capacitance enlarges when an over-long cable is used and thus high-harmonics current
may be easily generated.
If the length of the output cable is equal to or greater than the value in the following table,
install an AC output reactor on the power output side of the AC drive.