MD380 User Manual Operation, Display and Application Example
- 49 -
In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot
EHPRGL¿HG7KLVPD\EHEHFDXVH
Such a function code is only readable, such as, AC drive model, actually detected
parameter and running record parameter.
6XFKDIXQFWLRQFRGHFDQQRWEHPRGL¿HGLQWKHUXQQLQJVWDWHDQGFDQRQO\EHFKDQJHG
at stop.
4.3 Structure of )unction Codes
The MD380, an advanced product based on MD320, groups A and U, and new function
FRGHVWRJURXS)
)unction
Code Group
)unction Description
)0 to )9, )A
to )E, )P
Standard A
C drive
function code group
Compatible with MD320 series function codes and
adding some function codes.
A0 to A
8, AC
Advanced function
code group
Multi-motor parameters, AI/AO correction, optimization
control, PLC card extension function setting.
U0 to U3
Running state
function code group
Display of A
C drive basic parameters
In the function code display state, select the required function code by pressing the key
or DVVKRZQLQWKHIROORZLQJ¿JXUH
)LJXUH6HOHFWLQJWKHUHTXLUHGIXQFWLRQFRGH
)0
Level I menu
50.00
PRG
Shift
A0
AC
U0
)3
U3
:KHQ)3 -02 = 1x
:KHQ)3 -02 = x1
Press to display the
function code groups in turn .
:KHQ)3-02 = 0x (the value
of ten's digit is 0), group A is
invisible.
:KHQ)3-02 = x0 (the value
of unit's digit is 0), group U is
invisible.
Status parameters
(Default display)
(Select the function code group )
Press to display the function
code groups in reversed turn .