MD380 User Manual Function Code Table
- 99 -
Function
Code
Parameter Name
Setting Range
Default Property
*URXS)2XWSXW7HUPLQDOV
F5-00 FM terminal output mode
0: Pulse output (FMP)
1: Switch output (FMR)
0 ƿ
F5-01 FMR function selection
0: No output
1: AC drive running
2: Fault output
3: Frequency-level detection
FDT1 output
4: Frequency reached
5: Zero-speed running (no output
at stop)
6: Motor overload pending
7: AC drive overload pending
8: Set count value reached
9: Designated count value
reached
10: Length reached
11: PLC cycle completed
12: Accumulative running time
reached
13: Frequency limited
14: Torque limited
5HDG\IRU581
16: AI1 larger than AI2
17: Frequency upper limit reached
18: Frequency lower limit reached
(no output at stop)
8QGHUYROWDJHVWDWHRXWSXW
20: Communication setting
21: Reserved
22: Reserved
23: Zero-speed running 2 (having
output at stop)
24: Accumulative power-on time
reached
25: Frequency level detection
FDT2 output
26: Frequency 1 reached
27: Frequency 2 reached
28: Current 1 reached
2 ƿ
F5-02
Relay (T/A-T/B-T/C) function
selection
2 ƿ