MD380 User Manual Desc
ription of Function Codes
- 141 -
Function Code Parameter Name Setting Range Default
F0-02
Command
source selection
2SHUDWLRQSDQHOFRQWUROLQGLFDWRU2))
7HUPLQDOFRQWUROLQGLFDWRU21
2: Communication control (indicator
blinking)
0
It is used to determine the input channel of the AC drive control commands, such as run,
stop, forward rotation, reverse rotation and jog operation. You can input the commands in
the following three channels:
2SHUDWLRQSDQHOFRQWURO/2&$/5(027LQGLFDWRU2))
Commands are given by pressing keys
RUN
and
STOP
RES
on the operation panel.
7HUPLQDOFRQWURO/2&$/5(027LQGLFDWRU21
Commands are given by means of multifunctional input terminals with functions such
DV):'5(9-2*)DQG-2*5
&RPPXQLFDWLRQFRQWURO/2&$/5(027LQGLFDWRUEOLQNLQJ
Commands are given from host computer. If this parameter is set to 2, a communication
FDUG0RGEXV578352),%86'3FDUG&$1OLQNFDUGXVHUSURJUDPPDEOHFDUGRU
CANopen card) must be installed.
– ,ID352),%86'3FDUGLVVHOHFWHGDQG3='GDWDLVYDOLGFRPPDQGVDUHJLYHQ
by means of PZD1 data.
– If a user programmable card is selected, commands are written to A7-08 by
means of the programmable card.
– If any other card is selected, commands are written by means of the
communication address 0x2000.
Function Code Parameter Name Setting Range Default
F0-03
Main frequency
source X selection
0: Digital setting (non-retentive at power
down)
1: Digital setting (retentive at power down)
2: AI1
3: AI2
4: AI3
5: Pulse reference (DI5)
6: Multi-reference
7: Simple PLC
8: PID
9: Communication reference
0
It is used to select the setting channel of the main frequency. You can set the main
frequency in the following 10 channels: