EasyManua.ls Logo

Inovance MD380S2.2GB - Page 233

Inovance MD380S2.2GB
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MD380 User Manual Desc
ription of Function Codes
- 233 -
Function Code Parameter Name Setting Range Default
A2-47
Torque upper limit
source in speed
control mode
0: A2-48
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Communication reference
6: MIN (AI1,AI2)
7: MAX (AI1,AI2)
0
A2-48
Digital setting of
torque upper limit in
speed control mode
0.0%–200.0%
150.0%
A2-51
Excitation adjustment
proportional gain
0–20000
2000
A2-52
Excitation adjustment
integral gain
0–20000
1300
A2-53
Torque adjustment
proportional gain
0–20000
2000
A2-54
Torque adjustment
integral gain
0–20000
1300
A2-55
Speed loop integral
property
8QLWVGLJLW,QWHJUDOVHSDUDWHG
0: Disabled
1: Enabled
0
A2-61 Motor 2 control mode
0: SVC
1: CLVC
2: V/F control
0
A2-62
Motor 2 acceleration/
deceleration time
0: Same as motor 1
1: Acceleration/Deceleration time 1
2: Acceleration/Deceleration time 2
3: Acceleration/Deceleration time 3
4: Acceleration/Deceleration time 4
0
A2-63 Motor 2 torque boost
0.0%: Fixed torque boost
0.1%–30.0%
Model
dependent
A2-65
Motor 2 oscillation
suppression gain
0–100
Model
dependent
efesotomasyon.com

Table of Contents