Parameter Groups
‑411‑
Description
1: No input
16: When the linear speed is input through the preceding channels, the
maximum linear speed (B0‑05) must be set according to the per unit relationship.
The 1000H address is set according to the percentage. The 731AH address is
directly set by digit, and the digital setting range is from 0 to B0‑05.
B0-05
Maximum linear speed
Address:
0xB005
Min.:
0
Unit:
m/min
Max.: 6500 Data type: UInt16
Default:
1000
Change: In real time
Value Range:
0.0 m/min to 6500.0 m/min
Description
Used to set the maximum linear speed.
It corresponds to the actual linear speed when 100.0% is input for channel 1 to 5
of B0‑04. (It differs from the maximum linear speed required by production. Verify
them during settings.) When the linear speed is used to calculate the winding
diameter (B0‑07 = 0), the larger the parameter is, the larger the calculated winding
diameter is, and vice versa. According to this rule, the parameter can be corrected
according to the deviation between the calculated roll diameter and the actual
value.
B0-06
Minimum linear speed for winding diameter calculation
Address:
0xB006
Min.:
0
Unit:
m/min
Max.: 6500 Data type: UInt16
Default:
20
Change: In real time
Value Range:
0.0 m/min to 6500.0 m/min
Description
This parameter takes effect only when B0‑07 is set to 0.
When the linear speed is lower than the value of B0‑06, the current roll diameter is
maintained. When the linear speed is higher than the value of B0‑06, the roll
diameter is calculated. This parameter can be used to address inaccurate roll
diameter calculation for low‑frequency operation and acceleration.
B0-07
Winding diameter calculation method
Address:
0xB007
Min.:
0
Unit: