Parameter List
‑67‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A9‑06 0xA906 Speed feedback
handling in speed
control of
asynchronous
motor in SVC
mode
0: No operation
1: Minimum synchronization
frequency limited based on
load change
2: Fixed current output during
low‑speed running
3: Fixed current output during
low‑speed running
4: Low torque optimization
0 In real time "
A9‑06
"
on
page 366
A9‑07 0xA907 Magnetic field
regulation
bandwidth of
asynchronous
motor in SVC
mode
0.0 to 8.0 2 In real time "
A9‑07
"
on
page 366
A9‑08 0xA908 Low‑speed
running current of
asynchronous
motor in SVC
mode
30 to 170 100 In real time "
A9‑08
"
on
page 366
A9‑09 0xA909 Switchover
frequency of
output fixed
current of
asynchronous
motor in SVC
mode
0.1 Hz to 1.0 Hz 0.3 Hz At stop "
A9‑09
"
on
page 367
A9‑10 0xA90A Speed fluctuation
suppression
coefficient of
asynchronous
motor in SVC
mode
80 to 100 95 At stop "
A9‑10
"
on
page 367
A9‑11 0xA90B Acceleration/
Deceleration time
of asynchronous
motor in SVC
mode
10s to 3000s 200 s At stop "
A9‑11
"
on
page 367
A9‑12 0xA90C Quick auto‑tuning
of stator
resistance before
asynchronous
motor startup
0: Disabled
1: Enabled
0 At stop "
A9‑12
"
on
page 367

Table of Contents