Parameter List
‑69‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A9‑26 0xA91A Estimated
synchronous
motor speed
proportional gain
in SVC mode
5% to 300% 20 % In real time "
A9‑26
"
on
page 370
A9‑27 0xA91B Estimated
synchronous
motor speed filter
in SVC mode
10 to 2000 100 ‑ In real time "
A9‑27
"
on
page 371
A9‑28 0xA91C Minimum carrier
frequency of
synchronous
motor in SVC
mode
0.8 to F0‑15.0 2 ‑ In real time "
A9‑28
"
on
page 371
A9‑29 0xA91D Low speed
excitation current
of synchronous
motor in SVC
mode
0% to 80% 30 % In real time "
A9‑29
"
on
page 371
A9‑30 0xA91E Low‑speed closed‑
loop current (for
VVC)
0% to 65535% 0 % In real time "
A9‑30
"
on
page 371
A9‑31 0xA91F Oscillation
suppression
damping
coefficient (for
VVC)
0% to 65535% 0 % In real time "
A9‑31
"
on
page 372
A9‑32 0xA920 Reserved
parameter 8 for
synchronous
motor control
0 to 65535 0 ‑ In real time "
A9‑32
"
on
page 372
A9‑33 0xA921 Reserved
parameter 9 for
synchronous
motor control
0 to 5 0 ‑ At stop "
A9‑33
"
on
page 372
A9‑34 0xA922 Reserved
parameter 10 for
synchronous
motor control
0% to 65535% 0 % In real time "
A9‑34
"
on
page 372
A9‑35 0xA923 Performance fault
subcode upon 1st
fault
0 to 65535 0 ‑ Unchangea
ble
"
A9‑35
"
on
page 373
A9‑36 0xA924 Performance fault
subcode upon 2nd
fault
0 to 65535 0 ‑ Unchangea
ble
"
A9‑36
"
on
page 373
A9‑37 0xA925 Performance fault
subcode upon 3rd
fault
0 to 65535 0 ‑ Unchangea
ble
"
A9‑37
"
on
page 373