Parameter List
‑70‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
A9‑40 0xA928 Low‑speed closed‑
loop current
selection (for VVC)
0: Disabled
1: Enabled
0 ‑ At stop "
A9‑40
"
on
page 373
A9‑41 0xA929 Low‑speed closed‑
loop current (for
VVC)
30% to 200% 50 % At stop "
A9‑41
"
on
page 374
A9‑42 0xA92A Oscillation
suppression
damping
coefficient (for
VVC)
0% to 500% 100 % In real time "
A9‑42
"
on
page 374
A9‑43 0xA92B Initial position
compensation
angle (for VVC)
0 to 5 0 ‑ At stop "
A9‑43
"
on
page 374
A9‑44 0xA92C Initial position
compensation
angle of
synchronous
motor
0.0 to 360.0 0 ‑ In real time "
A9‑44
"
on
page 374
A9‑45 0xA92D Synchronous
motor low‑speed
handling
0: Disabled
1: Enabled
0 ‑ At stop "
A9‑45
"
on
page 375
A9‑46 0xA92E Switchover
frequency for
synchronous
motor low‑speed
handling
0.01 to F0‑10 5 ‑ At stop "
A9‑46
"
on
page 375
A9‑47 0xA92F Synchronous
motor low‑speed
handling current
10 to 200 100 ‑ At stop "
A9‑47
"
on
page 375
A9‑48 0xA930 Synchronous
motor low‑speed
handling feedback
suppression
coefficient
0 to 300 32 ‑ At stop "
A9‑48
"
on
page 375
A9‑49 0xA931 Synchronous
motor energy‑
saving control
0: Disabled
1: Enabled
0 ‑ At stop "
A9‑49
"
on
page 376
A9‑50 0xA932 Maximum flux
weakening current
limit margin
200–1000 1000 ‑ At stop "
A9‑50
"
on
page 376