You can set holding time and acceleration/deceleration time of 16 frequency references in
FC-18 to FC-49.
Function Code Parameter Name Setting Range Default
FC-18
Running time of simple PLC
reference 0
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-19
Acceleration/deceleration time of
simple PLC reference 0
0 to 3 0
FC-20
Running time of simple PLC
reference 1
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-21
Acceleration/deceleration time of
simple PLC reference 1
0 to 3 0
FC-22
Running time of simple PLC
reference 2
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-23
Acceleration/deceleration time of
simple PLC reference 2
0 to 3 0
FC-24
Running time of simple PLC
reference 3
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-25
Acceleration/deceleration time of
simple PLC reference 3
0 to 3 0
FC-26
Running time of simple PLC
reference 4
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-27
Acceleration/deceleration time of
simple PLC reference 4
0 to 3 0
FC-28
Running time of simple PLC
reference 5
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-29
Acceleration/deceleration time of
simple PLC reference 5
0 to 3 0
FC-30
Running time of simple PLC
reference 6
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-31
Acceleration/deceleration time of
simple PLC reference 6
0 to 3 0
FC-32
Running time of simple PLC
reference 7
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-33
Acceleration/deceleration time of
simple PLC reference 7
0 to 3 0
FC-34
Running time of simple PLC
reference 8
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-35
Acceleration/deceleration time of
simple PLC reference 8
0 to 3 0
FC-36
Running time of simple PLC
reference 9
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-37
Acceleration/deceleration time of
simple PLC reference 9
0 to 3 0
FC-38
Running time of simple PLC
reference 10
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-39
Acceleration/deceleration time of
simple PLC reference 10
0 to 3 0
FC-40
Running time of simple PLC
reference 11
0.0s (h) to 6553.5s (h) 0.0s (h)