EasyManua.ls Logo

Inovance MD500 Series - Safety Capacitance Box and Ferrite Core

Inovance MD500 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. Technical Data
- 268 -
9
Safety Capacitance Box and Ferrite Core
In some applications, connect safety capacitance box and wind a ferrite core to
remove some interference during drive running.
Connect safety capacitance box to grounding terminal of the drive, and ground cable
length cannot exceed 300 mm.
PE R S T
Cable length
< 300 mm
Cable length
< 300 mm
Cxy-1-1
Safety capacitance box
Magnetic ring
(Wind three turns)
Mounting dimensions of safety capacitance box
6.5 ± 0.2
4.5 ± 0.2
45 ± 0.5
65 ± 2
72 ± 2
38 ± 2
Brown
Brown
Brown
Yellow
green
65 ± 2
75 ± 0.5
85 ± 2
Unit: mm
Safety
Capacitance
Box Model
SN Overall Dimensions
(Length x Width x Height)
Mounting Dimensions
(Mounting Length x Mounting
Width) (mm)
Cxy-1-1 11025018 85 x 72 x 38 45 x 75

Table of Contents