Appendix. Parameter Table
- 311 -
Parameter
No.
Parameter Name Setting Range Default Property Page
F1-30 A/B phase sequence of ABZ
incremental encoder
0: Forward
1: Reserve
0
★
1
2
7
F1-34 Number of pole pairs of resolver 1 to 65535 1
★
1
2
7
F1-36 Encoder wire-break fault detection
time
0.0s: No detection
0.1s to 10.0s
0.0s
★
1
2
7
F1-37 Motor auto-tuning method
selection
0 to 3 0
★
1
2
7
Group F2: Vector Control Parameters
F2-00 Speed loop proportional gain 1 1 to 100 30
☆
1
3
4
F2-01 Speed loop integral time 1 0.01s to 10.00s 0.50s
☆
1
3
4
F2-02 Switchover frequency 1 0.00 to F2-05 5.00 Hz
☆
1
3
4
F2-03 Speed loop proportional gain 2 1 to 100 20
☆
1
3
4
F2-04 Speed loop integral time 2 0.01s to 10.00s 1.00s
☆
1
3
4
F2-05 Switchover frequency 2 F2-02 to max. frequency 10.00 Hz
☆
1
3
4
F2-06 SVC/FVC slip compensation gain 50% to 200% 100%
☆
1
3
4
F2-07 Speed feedback lter time
constant
0.000s to 0.100s 0.015s
☆
1
3
4
F2-09 Torque limit source in speed
control
0 to 7 0
☆
1
3
4
F2-10 Digital setting of torque limit in
speed control
0.0% to 200.0% 150.0%
☆
1
3
4
F2-11 Torque limit source in speed
control (in regenerative state)
0 to 7 0
☆
1
3
4
F2-12 Digital setting of torque limit in
speed control (in regenerative
state)
0.0% to 200.0% 150.0%
☆
1
3
6
F2-13 Excitation adjustment proportional
gain
0 to 60000 2000
☆
1
3
8
F2-14 Excitation adjustment integral
gain
0 to 60000 1300
☆
1
3
8
F2-15 Torque adjustment proportional
gain
0 to 60000 2000
☆
1
3
8
F2-16 Torque adjustment integral gain 0 to 60000 1300
☆
1
3
8
F2-17 Speed loop integral separation
selection
0: Disabled
1: Enabled
0
☆
-
F2-21 Max. torque coefcient of eld
weakening area
50% to 200% 100%
☆
1
3
8
F2-22 Regenerative power limit
selection
0: Disabled
1: Enabled in the whole
process
2: Enabled at constant
speed
3: Enabled during
deceleration
0
☆
1
3
6
F2-23 Regenerative power limit 0.0% to 200.0% Model
dependent
☆
1
3
6