- 76 -
CONTINUE Para. Parameter name Default Commission
If any digital output is used
Set DO function F5-01 FM (switch signal) function
selection
0
26: Frequency 1 reached
27: Frequency 2 reached
28: Current 1 reached
29: Current 2 reached
30: Timing duration reached
31: AI1 input limit exceeded
32: Load lost
33: Reverse running
34: Zero current status
35: Module temperature reached
36:Software current limit exceeded
37: Frequency lower limit reached (having output at stop)
38: Alarm output
39: Motor overheat warning
40: Current running time reached
41: Fault output (no output at undervoltage)
F5-02 Relay function selection(T/
A-T/B-T/C)
2
Setting range same as FM;
F5-03 Relay function selection (P/
A-P/B-P/C)
0
Setting range same as FM; the relay P/A-P/B-P/C is on
extension I/O card.
CONTINUE Para. Parameter name Default Commission