Appendix. Parameter Table
- 320 -
Parameter
No.
Parameter Name Setting Range Default Property Page
F9-68 Overspeed detection time 0.0s to 60.0s 1.0s
☆
1
4
5
F9-69 Detection level of speed error 0.0% to 50.0% (max.
frequency)
20.0%
☆
1
4
5
F9-70 Detection time of speed error 0.0s to 60.0s 5.0s
☆
1
4
5
F9-71 Power dip ride-through gain Kp 0 to 100 40
☆
1
4
4
F9-72 Power dip ride-through integral
coefcient
0 to 100 30
☆
1
4
4
F9-73 Deceleration time of power dip
ride-through
0.0s to 300.0s 20.0s
★
1
4
4
Group FA: PID Function
FA-00 PID reference setting channel 0 to 6 0
☆
1
0
5
FA-01 PID digital setting 0.0% to 100.0% 50.0%
☆
1
0
5
FA-02 PID feedback setting channel 0 to 8 0
☆
1
0
5
FA-03 PID operation direction 0, 1 0
☆
1
0
5
FA-04 PID reference and feedback range 0 to 65535 1000
☆
1
0
5
FA-05 Proportional gain Kp1 0.0 to 1000.0 20.0
☆
1
0
5
FA-06 Integral time Ti1 0.01s to 10.00s 2.00s
☆
1
0
5
FA-07 Differential time Td1 0.000s to 10.000s 0.000s
☆
1
0
5
FA-08 PID output limit in reverse
direction
0.00 Hz to max. frequency 0.00 Hz
★
1
0
6
FA-09 PID error limit 0.0% to 100.0% 0.0%
☆
1
0
6
FA-10 PID differential limit 0.00% to 100.00% 0.10%
☆
1
0
6
FA-11 PID reference change time 0.00s to 650.00s 0.00s
☆
1
0
6
FA-12 PID feedback lter time 0.00s to 60.00s 0.00s
☆
1
0
6
FA-13 PID output lter time 0.00s to 60.00s 0.00s
☆
1
0
6
FA-14 Reserved - -
-
-
FA-15 Proportional gain Kp2 0.0 to 1000.0 20.0
☆
1
0
7
FA-16 Integral time Ti2 0.01s to 10.00s 2.00s
☆
1
0
7
FA-17 Differential time Td2 0.000s to 10.000s 0.000s
☆
1
0
7
FA-18 PID parameter switchover
condition
0 to 3 0
☆
1
0
7
FA-19 PID error 1 for auto switchover 0.0% to FA-20 20.0%
☆
1
0
7
FA-20 PID error 2 for auto switchover FA-19 to 100.0% 80.0%
☆
1
0
7
FA-21 PID initial value 0.0% to 100.0% 0.0%
☆
1
0
7
FA-22 PID initial value active time 0.00s to 650.00s 0.00s
☆
1
0
7
FA-25 PID integral property 00 to 11 00
☆
1
0
8
FA-26 Detection level of PID feedback
loss
0.0%: No detection
0.1% to 100.0%
0.0%
☆
1
0
8
FA-27 Detection time of PID feedback
loss
0.0s to 20.0s 0.0s
☆
1
0
8
FA-28 Selection of PID operation at stop 0, 1 0
☆
1
0
8