7. Description of Parameters MD500 User Manual
- 172 -
Function Code Parameter Name Display Range
8 Feedback speed -320.00 to 320.00 Hz
-500.0 to 500.0 Hz
8,WGLVSOD\VWKHDFWXDORXWSXWIUHTXHQF\RIWKH$&GULYH
7KHWHQVGLJLWRI)1XPEHURIGHFLPDOSODFHVIRUORDGVSHHGGLVSOD\GHWHUPLQHVWKHQXPEHURIGHFLPDOSODFHVRI88

ƕ If the ten's digit is set to 2, the display range is -320.00 to 320.00 Hz.
ƕ If the ten's digit is set to 1, the display range is -500.0 to 500.0 Hz.
Function Code Parameter Name Display Range
U0-20 Remaining running time 0.0 to 6500.0 min
U0-20: It displays the remaining running time during the drive timing running.
Function Code Parameter Name Display Range
U0-21 AI1 voltage before correction 0.00 to 10.57 V
U0-22 $,YROWDJH9FXUUHQWP$EHIRUHFRUUHFWLRQ 0.00 to 10.57 V
0.00 to 20.00 mA
U0-23 AI3 voltage before correction -10.57 to 10.57 V
U0-21 to U0-23: They display the sampled AI input voltage (before correction). The actually used AI input voltage after correction
DUHGLVSOD\HGLQ88DQG8
Function Code Parameter Name Display Range
U0-24 Linear speed WRPPLQ
8,WGLVSOD\VWKHOLQHDUVSHHGRIWKH',XVHGIRUKLJKVSHHGSXOVHVDPSOLQJ7KHXQLWLVPHWHUPLQXWH7KHOLQHDUVSHHGLV
obtained according to the actual number of pulses sampled per minute and Fb-07 (Number of pulses per meter).
Function Code Parameter Name Display Range
U0-27 Pulse reference 0 to 65535 Hz
U0-27: It displays the DI5 high-speed pulse sampling frequency, in minimum unit of 1 Hz. It is the same as U0-18, except for the
difference in units.
Function Code Parameter Name Display Range
U0-28 Communication reference -100.00% to 100.00%
U0-28: It displays the data written by means of the communication address 0x1000.
Function Code Parameter Name Display Range
8 Encoder feedback speed -320.00 to 320.00 Hz
-500.0 to 500.0 Hz
8,WGLVSOD\VWKHPRWRUUXQQLQJIUHTXHQF\PHDVXUHGE\WKHHQFRGHU
7KHWHQVGLJLWRI)1XPEHURIGHFLPDOSODFHVIRUORDGVSHHGGLVSOD\GHWHUPLQHVWKHQXPEHURIGHFLPDOSODFHVRI88

ƕ If the ten's digit is set to 2, the display range is -320.00 to 320.00 Hz.
ƕ If the ten's digit is set to 1, the display range is -500.0 to 500.0 Hz.