13. EMC MD500 User Manual
- 310 -
ƕ Physical appearance of the magnetic ring
ƕ Selection of the magnetic ring
Magnetic Ring Model SN Dimensions
(Outer Diameter x Inner Diameter x Thickness)
(mm)
DY644020H 11013031 64 x 40 x 20
DY805020H 11013032 80 x 50 x 20
DY1207030H 11013033 120 x 70 x 30
13.5.2 AC Input Reactor Installation
Ƶ
AC Reactor Model
The AC input reactor is connected to suppress harmonic current on the input side. Install an AC reactor when the application has
higher requirements on harmonic suppression.
The recommended AC reactor manufacturer and models are listed in the following table.
AC Drive Model AC Reactor Model
(Inovance)
MD500T18.5 MD-ACL-50-4T-183-2%
MD500T22 MD-ACL-60-4T-223-2%
MD500T30 MD-ACL-80-4T-303-2%
MD500T37 0'$&/7
MD500T45 MD-ACL-120-4T-453-2%
MD500T55 MD-ACL-150-4T-553-2%
MD500T75 MD-ACL-200-4T-753-2%
0'7 MD-ACL-250-4T-114-2%
MD500T110 MD-ACL-250-4T-114-2%
Ƶ
Designation Rule
Inovance AC Input Reactor
4T
380 V
MD-ACL
50
Rated Current
50 A
Mark
50
Mark
4T
Rated Voltage
2%
Voltage Drop Percentage
2%
2%
Mark
183
Applicable Power
18.5 kW
Mark
183