MD500 User Manual 3. Electrical Installation
- 51 -
Type Terminal
Name
Description
Digital
outputs
DO1 CME Digital output 1 Optically-coupled isolation, dual-polarity open
collector output
Output voltage range: 0 to 24 V
Output current range: 0 to 50 mA.
Note that CME and COM are internally insulated, but are shorted
H[WHUQDOO\E\DMXPSHU,QWKLVFDVH'2LVGULYHQE\9E\
GHIDXOW5HPRYHWKHMXPSHUOLQNLI\RXQHHG
to apply external power to DO1.
FM COM High-speed pulse output Controlled by F5-00 (FM terminal output selection).
Max. output frequency: 100 kHz.
When used as an open-collector output, the
VSHFLÀFDWLRQLVWKHVDPHDVIRU'2
Relay
outputs
7$ 7% Normally-closed
(NC) terminal
Contact driving capacity:
250 VAC, 3 A, Cos f = 0.4
30 VDC, 1 A
7$ 7& Normally-open
(NO) terminal
Auxiliary
interfaces
J13 Extension card interface ,QWHUIDFHIRUWKHFRUHWHUPLQDODQGRSWLRQDOFDUGV,
O extension card, PLC card and various bus cards)
J4 PG card interface Open-collector, UVW and Resolver are selectable options.
J11 External operating
panel interface
Connect to an external operating panel.
Ƶ
Cable Dimensions and Tightening Torque
Please use the ferrule-type terminal with insulated sleeves. In the scenarios where single wire or twisted wire is applied, keep
WKHVWULSOHQJWKRIPPDVVKRZQLQWKHIROORZLQJÀJXUH
)LJXUH5HTXLUHPHQWRIIHUUXOHWHUPLQDO
6 mm
7DEOH&DEOHGLPHQVLRQVDQGWLJKWHQLQJWRUTXH
Terminal Block Single Wire mm
2
(AWG) Twisted Wire mm
2
(AWG) Tightening Torque
Control circuit 0.2 to 0.75
(AWG24 to 18)
0.8 to 1.0
7DEOH&DEOHVSHFLÀFDWLRQDQGIHUUXOHWHUPLQDOPRGHO
&DEOH6SHFLÀFDWLRQPP
2
(AWG) Ferrule Terminal Model Strip Length
0.75 (18) 0.75-8GY
6 mm
efesotomasyon.com