Common Parameter Settings
‑79‑
Param
eter
Code
Commu
nication
Address
Parameter Name Value Default Unit Change
Mode
A6‑10 0xA60A Format displayed
by free mapping 1
Ones: Unit
0: None
1: Hz
2: A
3: RPM
4: V
5: Link
6: %
7: s
8: h
9: kW
10: kW/h
11: °C
Tens: Number of decimal places
0: 0
1: 1
2: 2
3: 3
4: 4
Hundreds: Settings of the ones and tens
places
0: Invalid
1: Valid
0 Real time
A6‑15 0xA60F Number of decimal
places of floating
connector
0: Two decimal places
1: One decimal place
1 Real time
A6‑16 0xA610 LED display of
direction
Ones: Direction display at stop
0: Not displayed
1: Displayed
Tens: Running direction determination
base
0: Output frequency
1: Feedback frequency
1 Real time
A6‑17 0xA611 LED display update
cycle
10 ms to 300 ms 10 ms Real time
A6‑18 0xA612 Error pop‑up time 1s to 60s 10 s Real time
A6‑20 0xA614 LED operating
panel key test
0: Inactive
1: Active
0 At stop
A6‑21 0xA615 Key test result 0 to 65535 0 Unchangea
ble