Common Parameter Settings
‑89‑
Param
eter
Code
Commu
nication
Address
Parameter Name Value Default Unit Change
Mode
U0‑61 0x703D AC drive state 1 1: Forward running
2: Reverse running
3: Stopped
4: Auto‑tuning
5: Faulty
0 ‑ Unchangea
ble
U0‑65 0x7041 Torque upper limit ‑2000.0% to 2000.0% 0.0 % Unchangea
ble
U0‑68 0x7044 AC drive state 2 0 to 65535 0 ‑ Unchangea
ble
U0‑69 0x7045 AC drive running
frequency 2
(signed)
‑327.67 Hz to 327.67 Hz 0.00 Hz Unchangea
ble
U0‑70 0x7046 Motor running
speed 2 (signed)
‑32768 RPM to +32767 RPM 0 RPM Unchangea
ble
U0‑71 0x7047 Output current
display 2
0.0 A to 6553.5 A 0.0 A Unchangea
ble
U0‑74 0x704A AC drive output
torque
‑200.0% to 200.0% 0.0 % Unchangea
ble
U0‑75 0x704B AC drive running
frequency 3
(unsigned)
0.00 Hz to 655.35 Hz 0.00 Hz Unchangea
ble
U0‑76 0x704C Low‑order bits of
cumulative power
consumption
0.0 kW·h to 6553.5 kW·h 0.0 kW·h Unchangea
ble
U0‑77 0x704D High‑order bits of
cumulative power
consumption
0 kW·h to 65535 kW·h 0 kW·h Unchangea
ble
U2‑01 0x7201 Current control
channel
0: Control channel 1
1: Control channel 2
0 ‑ Unchangea
ble
U2‑02 0x7202 Current set channel 0: Set channel 1
1: Set channel 2
0 ‑ Unchangea
ble
U2‑03 0x7203 Jump frequency
flag
0 to 65535 0 ‑ Unchangea
ble
U2‑04 0x7204 Local/remote 0: Remote
1: Local
0 ‑ Unchangea
ble
U2‑05 0x7205 Current multi‑
speed selection
0 to 65535 0 ‑ Unchangea
ble
U2‑06 0x7206 Current multi‑
speed effective
value
‑3276.7% to 3276.7% 0.0 % Unchangea
ble
U2‑07 0x7207 Key value 0 to 65535 0 ‑ Unchangea
ble
U2‑08 0x7208 Power‑off time 0 to 65535 0 ‑ Unchangea
ble