Para.
No.
Address
Name
Value Range
Default
Unit
Change
Page
F8-19 63507
Accumulative power-on
time threshold setting
0 h to 65000 h
0
h
At once
“
F8-19
”
on page
283
F8-20 63508
Accumulative running
time threshold setting
0 h to 65000 h
0
h
At once
“
F8-20
”
on page
283
F8-21 63509
Startup protection
selection
0: Disabled
1: Enabled
0 - At once
“
F8-21
”
on page
284
F8-22 63510
Frequency detection
value 1 (FDT1)
0.00 Hz to 655.35 Hz 50.00 Hz At once
“
F8-22
”
on page
284
F8-23 63511
Frequency detection
hysteresis 1 (FDT1)
0.00 to F8-22 2.50 Hz At once
“
F8-23
”
on page
284
F8-24 63512
Frequency detection
value 2 (FDT2)
0.00 Hz to 655.35 Hz 50.00 Hz At once
“
F8-24
”
on page
284
F8-25 63513
Frequency detection
hysteresis 2 (FDT2)
0.00 Hz to 655.35 Hz 2.50 Hz At once
“
F8-25
”
on page
285
F8-26 63514
Frequency detection
range
0.00 Hz to 655.35 Hz 2.50 Hz At once
“
F8-26
”
on page
285
F8-27 63515
Detection value 1 for
frequency reach
0.00 Hz to 655.35 Hz 50.00 Hz At once
“
F8-27
”
on page
285
F8-28 63516
Detection frequency 1
for frequency reach
0.00 to F8-28 2.50 Hz At once
“
F8-28
”
on page
285
F8-29 63517
Detection mode for
frequency reach 1
0: Always detect
1: Not detect during acceleration/
deceleration
0 -
At stop
“
F8-29
”
on page
285
F8-30 63518
Detection value 2 for
frequency reach
0.00 Hz to 655.35 Hz 50.00 Hz At once
“
F8-30
”
on page
286
F8-31 63519
Detection frequency 2
for frequency reach
0.00 to F8-28 2.50 Hz At once
“
F8-31
”
on page
286
F8-32 63520
Detection mode for
frequency reach 2
0: Always detect
1: Not detect during acceleration/
deceleration
0 -
At stop
“
F8-32
”
on page
286
F8-35 63523
Switchover frequency of
acceleration time 1 and
acceleration time 2
0.00 Hz to 655.35 Hz 0.00 Hz At once
“
F8-35
”
on page
286
List of Drive Unit Parameters