Commissioning and Trial Run
108
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
FC‑47 64559 Acceleration/
Deceleration time of
PLC reference 14
03 0 Modifiable
in any states
FC‑48 64560 Running time of PLC
reference 15
0.0s (h) to 6553.5s (h) 0.0 s (h) Modifiable
in any states
FC‑49 64561 Acceleration/
Deceleration time of
PLC reference 15
03 0 Modifiable
in any states
FC‑50 64562 Time unit of PLC
running
0: s (second)
1: h (hour)
0 Modifiable
in any states
FC‑51 64563 Reference 0 source 0: Reference 0 (FC‑00)
1: AI1
2: AI2
3: AI3
4: Reserved
5: PID
6: Preset frequency (F0‑
08), modified by terminal
UP/DOWN
0 Modifiable
in any states
FD‑02 64770 Local address 0247 1 Modification
prohibited
FD‑06 64774 Communication fault
reset
01 1 Modifiable
only at stop
FD‑08 64776 Last assigned station
No.
065535 0 Modification
prohibited
FD‑09 64777 CANopen/CANlink
communication state
Ones: CANopen
0: Stop
1: Initialized
2: Pre‑running
8: Running
Tens: CANlink
0: Stop
1: Initialized
2: Pre‑running
8: Running
0 Modification
prohibited
FD‑10 64778 CANopen/CANlink
switchover
1: CANopen
2: CANlink
1 Modification
prohibited
FD‑11 64779 CANopen402 protocol 0: Disabled
1: Enabled
0 Modifiable
only at stop
FD‑13 64781 CAN station No. 1127 1 Modifiable
only at stop
FD‑14 64782 Received CAN frames
per unit of time
065535 1 Modification
prohibited
FD‑19 64787 CAN communication
interruption
coefficient
115 1 Modifiable
only at stop