Commissioning and Trial Run
‑113‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
(continued) 41216 VDI1 function
selection
25: Switchover between
auxiliary frequency
reference Y and preset
frequency
26: Frequency
modification enable
27: Counter input
28: Counter reset
29: Length count input
30: Length reset
31: PID pause
32: PID integral pause
33: PID parameter
switchover
34: PID action direction
reverse
35: Torque control
prohibited
36: Speed control/Torque
control switchover
38: Speed tracking
enabled
39: Immediate DC braking
40: Deceleration DC
braking
41: External stop terminal
1
42: External stop terminal
2
43: Running pause
44: Coast to stop
45: Emergency stop
46: Motor selection
terminal
47: Clear the current
running time
48: Two‑wire/Three‑wire
switchover
49: PLC state reset
50: Wobble pause
54–63: Reserved
0 ‑ Modifiable
only at stop
A1‑01 41217 VDI2 function
selection
Same as A1‑00 0 ‑ Modifiable
only at stop
A1‑02 41218 VDI3 function
selection
Same as A1‑00 0 ‑ Modifiable
only at stop
A1‑03 41219 VDI4 function
selection
Same as A1‑00 0 ‑ Modifiable
only at stop