Commissioning and Trial Run
‑61‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
U0‑23 28695 Current power on
time millisecond
01000 ms 0 ms Modification
prohibited
U0‑25 28697 Braking unit control
command word
0: Braking disabled
1: Braking
0 Modification
prohibited
U0‑30 28702 Total power‑on time
hour
065535 h 0 h Modification
prohibited
U0‑31 28703 Total power‑on time
minute
060 min 0 min Modification
prohibited
U0‑32 28704 Total power‑on time
second
0s to 60s 0 s Modification
prohibited
U0‑33 28705 Total power‑on time
millisecond
01000 ms 0 ms Modification
prohibited
U0‑35 28707 Power supply unit
state
0: Normal running
1: No RST input
2: Fault state
0 Modification
prohibited
U2‑00 29184 Power supply unit I/O
type
065535 0 Modification
prohibited
U2‑01 29185 Power supply unit I/O
version
0.00655.35 2 Modification
prohibited
U2‑02 29186 Power supply unit I/O
original DI hardware
resource
08 0 Modification
prohibited
U2‑03 29187 Power supply unit I/O
available DI
hardware resource
08 0 Modification
prohibited
U2‑04 29188 Power supply unit I/O
original AI hardware
resource
02 0 Modification
prohibited
U2‑05 29189 Power supply unit I/O
available AI
hardware resource
02 0 Modification
prohibited
U2‑06 29190 Power supply unit I/O
original DO
hardware resource
08 0 Modification
prohibited
U2‑07 29191 Power supply unit I/O
available DO
hardware resource
08 0 Modification
prohibited
U2‑08 29192 Power supply unit I/O
original AO
hardware resource
02 0 Modification
prohibited
U2‑09 29193 Power supply unit I/O
available AO
hardware resource
02 0 Modification
prohibited
U2‑10 29194 Power supply unit I/O
DI input
065535 0 Modification
prohibited