What to do if Inovance Monarch 220-NICE-L-C-4011 Controller shows overcurrent during acceleration?
P
Philip BonillaSep 22, 2025
If the Inovance Controller experiences overcurrent during acceleration, several factors could be at play. First, examine the motor and grounding cables to ensure they are correctly connected and that the motor cables do not have damaged jackets. Also, check for short circuits at the controller output side, especially from shorting PMSM stator contactors. Another potential cause is incorrect motor parameters or improper auto-tuning; verify the motor parameters against the nameplate and repeat the motor auto-tuning process. You may also need to reduce the acceleration rate if the acceleration time is too short. Finally, ensure that the phase sequence of the motor is correct by exchanging the motor UVW phase sequence.
Inovance Monarch 220-NICE-L-C-4011 Specifications
General
Model
220-NICE-L-C-4011
Control mode
Vector control
Rated voltage
220V
Storage Temperature
-20°C to +60°C
Product name
Monarch 220
Series
Monarch
Protection Features