Loading...
- 100 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-41
Program control selection
2
Bit2: Inspection to stop due to
slow-down 1
Bit4: Buzzer tweet during door
open delay
Bit6: Cancelling door open delay
Bit8: Elevator lock at door open
Bit9: Display available at elevator
lock
Bit10: Elevator lock in the
attendant state
Bit11: Blinking at arrival (within the
time set in F6-47)
Bit12: Door re-open during door
open delay
Bit13: Door re-open after car call
of the present oor
0 -
ā˜…
F6-41 is used to select program control functions. Each bit of the parameter denes a function, as described in
the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-41 are described in the following table.
Bit Function Description Default
Bit0 Reserved - 0
Bit1 Reserved - 0
Bit2
Inspection to stop due to
slow-down 1
During inspection running, if the slow-down 1 acts, the system
decelerates to stop.
0
Bit3 Reserved - 0
Bit4
Buzzer tweet during door
open delay
The buzzer will tweet when the door open delay time set in Fb-14
is reached.
0
Bit5 Reserved - 0
Bit6
Cancelling door open
delay
Door open delay is cancelled when the door open delay button is
pressed again.
0
Bit7 Reserved - 0
Bit8 Elevator lock at door open
In the elevator lock state, the elevator keeps the door open at the
elevator lock oor.
0
Bit9
Display available at
elevator lock
In the elevator lock state, hall calls are displayed normally. 0
Bit10
Elevator lock in the
attendant state
The elevator is locked properly in the attendant state. 0
Bit11 Blinking at arrival
The car display blinks when the elevator arrives at a oor. The
blinking advance time is set in F6-47.
0
Bit12
Door re-open during door
open delay
The door re-opens if the door open delay input is active during
door close.
0
Bit13
Door re-open after car
call of the present oor
The door re-opens if the car call of the present oor is valid during
door close.
0