Chapter 6 Description of Function Codes
- 86 -
The meaning of each segment is dened in the following table.
Segment
(LED1)
Meaning of ON
Segment
(LED2)
Meaning of ON
Segment
(LED3 &
LED4)
Meaning
of ON
A
Door open limit signal
output 0
A
Door lock signal
output
Reserved Reserved
B
Door close limit signal
output 0
B
Door re-open
signal output
C
Door open limit signal
output 1
C
Hindering signal
output
D
Door close limit signal
output 1
D
Reserved
E Fault signal output 1 E
F Reserved F
G
Door open limit signal
output 2
G
DP
Door close limit signal
output 2
DP
Function Code Parameter Name Setting Range Default Min. Unit
FA-21
Parameter display selection
0–9999 0 1
FA-22
Display 1
0–9999 0 1
FA-23
Display 2
0–9999 0 1
FA-21 is used to set the actually displayed content of FA-22 and FA-23 for fault identication
and commissioning onsite. The meanings of values are as follows:
Value Displayed Content of FA-22 Displayed Content of FA-23
1
Average speed within 1s (Hz)
Average value of speed uctuation within 1s
(Hz)
2
Maximum speed within 1s (Hz) Minimum speed within 1s (Hz)
3
Slip frequency (Hz) Actual feedback frequency (Hz)
4
Excitation current component (A) Torque current component (A)
Other
Number of pulses received from the
encoder within 1s (high bit)
Number of pulses received from the encoder
within 1s (low bit)
Function Code Parameter Name Setting Range Default Min. Unit
FA-24 Analog voltage display 0.00–10.10 V 0.00 V 0.01 V
It is used to display the sampled analog voltage in real time.
Function Code Parameter Name Setting Range Default Min. Unit
FA-25 Low bits of current door position 0–9999 0 1