Keypad
64
No. Name
Function
Name
Description
Remarks
31
HomeSwitch Home switch
Disabled Mechanical
load beyond the home
switch range
Enabled Mechanical
load within the home
switch range
The corresponding
terminal logic must be
level‑triggered.
34
EmergencyStop
Emergency
stop
Enabled: Position lock
applied after stop at
zero speed
Disabled: Current
operating state
unaffected
The corresponding
terminal logic is
recommended to be level‑
triggered.
38
TouchProbe1
Touch probe
1
Disabled Touch probe
not triggered
Enabled Touch probe
triggerable
The touch probe logic is
only related to the touch
probe function (60B8h).
39
TouchProbe2
Touch probe
2
Disabled Touch probe
not triggered
Enabled Touch probe
triggerable
The touch probe logic is
only related to the touch
probe function (60B8h).
Description of DO Signals
01 S‑RDY
Servo ready
Enabled Servo ready
Disabled Servo not
ready
The servo drive is ready to
run.
02 TGON
Motor
rotation
Disabled The absolute
value of filtered motor
speed is lower than the
setpoint; H06‑16.
Enabled The absolute
value of filtered motor
speed reaches the
setpoint of H06‑16.
09 BK
Brake output
Enabled Brake signal
outputted
Disabled Brake signal
not outputted
10 WARN
Warning
Enabled Warning
occurred on the servo
drive
Disabled No warning
occurred on the servo
drive or the warning
has been reset