EasyManua.ls Logo

Inovance SV670P Series - Page 74

Inovance SV670P Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of Fault Codes
‑73‑
Cause
Confirming Method
Solution
5. An error occurs on the
communication between the
servo drive and the encoder.
Check whether the value of
H0b.28 is not 0.
1. Check whether H00.00
(Motor code) is set
properly.
2. Check whether the
encoder cable is
connected properly.
3. Check whether the servo
drive and motor are
grounded properly. You
can wind a magnetic ring
on the encoder cable to
reduce interference.
E740.3: Absolute encoder single‑turn calculation error
Cause:
The encoder is faulty.
Cause
Confirming Method
Solution
An encoder fault occurs.
Replace with a new encoder
cable. If the fault no longer
occurs after cable
replacement, it indicates the
original encoder cable is
damaged. Keep the motor in
a certain position, power on
the system several times
and observe the change of
H0b.17 (Electrical angle).
The electrical angle
deviation should be within
±30° when the motor
position does not change.
1. Check whether the
encoder version (H00.04)
is proper.
2. Check whether the
encoder cable is proper.
3. Replace the motor.
E740.6: Encoder data write error
Cause:
The attempt to write the encoder data fails.

Other manuals for Inovance SV670P Series

Related product manuals