ZeroWire Installation Manual 51
Zone Type
The zone type can be changed using the ZeroWire keypad to one of the following defaults.
If you require further customization please use the ZeroWire Web Server, UltraSync + app,
or DLX900 to access more advanced settings.
Voice Zone Type Zone Options
Delay Zone Type 3 Entry Exit Delay 1 1 Bypass
Delay Zone Type with Bypass in Stay Mode 3 Entry Exit Delay 1 2 Bypass Stay
No Delay Zone Type 6 Instant 1 Bypass
No Delay Zone Type with Bypass in Stay Mode 6 Instant 2 Bypass Stay
24 Hour Zone Type 2 24 Hour Audible 6 Panic
24 Hour Silent Zone Type 7 24 Hour Silent 7 Silent Panic
Smoke Zone 8 Fire Alarm 5 Fire
Configuring Zone Names
All zones can be named using library words on page 106. This makes it easier to identify
the correct detector in the event of a condition. You may enter up to eight words to achieve
your desired description.
Example: Configure zone 1 name as “Dining Room Zone”
1.
Select main menu - Option 6, Basic system
configuration.
2.
Enter your Installer code.
3.
Select zone name recording.
4.
Select zone 1.
5.
Select word “Dining” from the word library.
Select word “Room” from the word library.
Select word “Zone” from the word library.
6.
Exit from the menu.
If you do not require all eight words, just press MENU as in step 6 after you have entered
the last word number.
YOUR 4 TO 8 DIGIT INSTALLER CODE