ZeroWire Installation Manual 93
Connecting Inputs
ZeroWire has two general purpose inputs located on the rear of the unit. These can be
connected to up to 4 devices when Zone Doubling is enabled. Use the supplied header
cable.
To disable the inputs:
• Set System Menu -> General Options -> Disable Hardwired Zones = ON
To enable 2 inputs:
• Set System Menu -> General Options -> Disable Hardwire zones = OFF
• Set System Menu -> General Options -> Panel Zone Doubling = OFF
• Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
or OFF for no tamper
To enable 4 inputs without tamper monitoring:
• Set System Menu -> General Options -> Disable Hardwire Zones = OFF
• Set System Menu -> General Options -> Panel Zone Doubling = ON
• Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
• If hard wired inputs are programmed as zone 1, 2, 3, and/or 4, then these will take
priority over the wireless detectors.
• System Double EOL will take priority over Zone EOL setting. If Zone EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
• Normally Open or Normally Closed state can be set in Zone Options -> Options.