ZeroWire Installation Manual 93
Connecting Inputs
ZeroWire has two general purpose inputs located on the rear of the unit. These can be
connected to up to 4 devices when Zone Doubling is enabled. Use the supplied header
cable.
Input/Output
Connector
1. Gr
ound
2. Input 1
3. Input 2
4. Output 1
5. Output 2
6. 8.5V+
Pin Outs
To disable the inputs:
Set System Menu -> General Options -> Disable Hardwired Zones = ON
To enable 2 inputs:
Set System Menu -> General Options -> Disable Hardwire zones = OFF
Set System Menu -> General Options -> Panel Zone Doubling = OFF
Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
or OFF for no tamper
To enable 4 inputs without tamper monitoring:
Set System Menu -> General Options -> Disable Hardwire Zones = OFF
Set System Menu -> General Options -> Panel Zone Doubling = ON
Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
If hard wired inputs are programmed as zone 1, 2, 3, and/or 4, then these will take
priority over the wireless detectors.
System Double EOL will take priority over Zone EOL setting. If Zone EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
Normally Open or Normally Closed state can be set in Zone Options -> Options.
Input/Output
Connector
Pins
1. Ground
2. Input 1
3. Input 2
4.
Output 1
5. Output 2
6. 8.5 V+