Customizing Reporting Codes
The ZeroWire control panel has the ability to report Ademco Contact I.D. transmissions.
Each report in Contact I.D. consists of an event code and the zone I.D. generating the
alarm.
Programmed
Event Code
Contact I.D. Code SIA Event Code Description
0
Use default code for Zone Type Use default code for Zone Type
1
110 FA Fire Alarm
2
120 PA Panic Alarm
3
130 BA Burglary Alarm
4
131 BA Perimeter Alarm
5
132 BA Interior Alarm
6
133 UA 24 Hour (Safe)
7
134 BA Entry/Exit Alarm
8
135 BA Day/Night Alarm
9
150 UA Non Burglary 24 Hour
10
121 HA Duress Alarm
11
122 HA Silent Panic
12
100 MA Medical Alarm
13
123 PA Audible Panic Alarm
14
137 TA Tamper Alarm
15
602 RP Periodic Test
16
151 GA Gas Detected
17
158 KA High Temp
18
154 WA Water Leakage
19
140 QA General Alarm
20
140 SA General Alarm
21
159 ZA Low Temp
22
158 KH High Temp
23
115 FA Fire Alarm Pull Station
Note: Events are processed in the order they occur. The priority of presentation is
determined in by ARC monitoring centre and the automation software.
Customize the code reported by following these steps:
1. Log in to the Web Server.
2. Click Advanced\Zone Options.
3. Select the Zone Options you want to change.