Do you have a question about the inTest Temptronic ThermoChuck TP03000 Series and is the answer not in the manual?
Brand | inTest |
---|---|
Model | Temptronic ThermoChuck TP03000 Series |
Category | Industrial Equipment |
Language | English |
Critical warnings regarding electrical hazards, proper handling, and temperature limits.
Important cautions for preventing equipment damage and ensuring safe operation.
Step-by-step guide for powering on and initiating the system's start-up sequence.
Procedure for modifying the primary (T1, T2) temperature setpoints using the front panel.
Steps to set and monitor the ThermoChuck temperature at selected setpoints.
Explains how to set up and initiate automatic temperature cycling sequences.
Details the pin allocations for the 25-pin connector and handshake methods.
Describes configurable parameters for the RS-232C interface, such as baud rate and parity.
Lists and explains the six commands used for remote control of the system via RS-232C.
Explains how the system requests service and the format of the status byte.
Describes configurable parameters for the GPIB interface, such as SRQ mask and address.
Lists and explains commands and queries for the IEEE-488.1 standard.
Details commands used to send specific data from the controller to the remote computer.
Lists and explains commands and queries for the IEEE-488.2 standard.
Lists commands for receiving setpoint and other data from the remote computer.
Lists queries for sending status and parameter data from the controller to the remote computer.
Explains the SRQ mechanism and the SRQ mask for IEEE-488 communication.
Procedures for weekly inspection and regular cleaning of system components.
Steps to verify the system's temperature calibration accuracy against a known standard.
Detailed instructions for performing a two-point system calibration.
Instructions for adding coolant to the system's reservoir.
Instructions for safely draining coolant from the system.
Procedure for flushing the system's coolant lines.
Steps for checking battery voltage and replacing batteries if necessary.
Explains common error messages displayed by the TP03000 Controller.
Guidelines for correctly installing internal Teflon ferrule type coolant fittings.
Information on recognizing and identifying damaged flare fittings.
Exposure Controls/Personal Protection
Information on potential health effects from overexposure to Galden HT 110.
Recommended first aid procedures for exposure to Suva 95 (R-508B).
Information on fire hazards and fighting procedures for Suva 95 (R-508B).