30
MAINTENANCE
Cleaning the Drain Pump Filter
Make sure that valve cap and emergency drain hose are reinstalled properly, cap
plates should be inserted aligning to hole plates otherwise water may leak.
Some machines don’t have emergency drain hose, so step 2 and step 3 can be skipped.
Rotate lower cover cap directly to make water run into basin.
When the appliance is in use and depending on the programme selected there can
be hot water in the pump. Never remove the pump cover during a wash cycle, always
wait until the appliance has finished the cycle, and is empty. When replacing the
cover, ensure it is securely re-tightened.
Allow detergent solution to cool down.
Unplug the machine to avoid electrical shock before washing.
Drain pump filter can filter the yarns and small foreign matters from the
washing.
Clean the filter periodically to ensure the normal operation of washing
machine.
Be careful of the hot water!
Warning!
Caution!
Open the lower cover cap
Open the filter by turning
to the counter clockwise
Remove extraneous matter
1
Close the lower cover cap
4
3
2