In the default main interface, press the MENU key to enter the main menu, press the DOWN key to
select the system information, press the ENTER key to enter the system information, press the
MENU key to return to the main interface.
In the default main interface, press the MENU key to enter the main menu, press the DOWN key to
select the communication setting, press the ENTER key to enterthe communication settings, press
the UP key to select the baud rate setting orthe local address setting, press the DOWN key to set
the baud rate and the local address value, press the ENTER key to confirm, after hearthe
continuous tone and press the MENU key to return to the previous menu and the main interface.
In the default main interface, press the MENU key to enter the main menu, press the DOWN key
to select the DC output setting, press the ENTER key to enter the DC output setting, press the
DOWN key to selectOFF, AUTO, TIME CONTROL. When you select Off or Auto, press ENTERto
confirm, and when you select TIME CONTROL, it needs select time period to turn on and off the
DC output. Press the DOWN key to select the time control and press the UP key to move the
cursor. Press the DOWN key to enter the time value. Press the ENTER key to confirm, after
hearthe continuous tone and press the MENU key to return to the previous menu and the main
interface.
Note: The turn off is directly turn off the DC output, automatic is opening the DC output after MP
PT connect to the battery, except for the battery undervoltage, and time control is to open and close
the DC output according the time period setting.
Note: The operation parameter s
etting must be conducted by qualified electrical engineering
per
sonnel, otherwise the mis-operaton might cause the MPPT does not work or damage
the battery.
In the default main interface, press the MENU button to enter the main menu, press the DOWN key
to select the run parameter setting, press the ENTER key to enter the password prompt interface,
enter the password and press ENTER to enter the run parameter setting.
Note: Before setting the operating parameters, you must disconnect the PV module from the
MPPT controller. Then in order set below parameter: 1. battery type setting, 2. the rated
voltage setting, 3. the charging voltage setting, 4. the charging current setting, 5.the
discharging lower limit setting. And then check the displayed parameter of system
information whether it is consistent or not.