Goodrive350 series high-performance multi-function inverter Chapter 6
-183-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P12.24
Initial pole
position of
synchronous
motor 2
(reserved)
00xFFFF
0x0000
P12.25
Identification
current of
synchronous
motor 2
(reserved)
0%50% (rated motor current)
10%
P12.26
Overload
protection of
motor 2
0: No protection
1: Common motor (with low-speed compensation)
2: Frequency-variable motor (without low-speed
compensation)
2
P12.27
Overload
protection
coefficient of
motor 2
Motor overload multiples M = Iout/(In×K)
In is rated motor current, lout is inverter output
current, K is motor overload protection coefficient.
The smaller the K, the larger the value of M, the
easier the protection.
if M is 116%, protection will be applied when motor
overloads for 1h; if M is 200%, protection will be
applied when motor overloads for 60s; if M is no less
than 400%, protection will be applied immediately.
1min
1h
116 % 200 %
Time t
Motor overload multiples
Setting range: 20.0%120.0%
100.0%
P12.28
Power display
calibration
coefficient of
motor 2
0.003.00
1.00
P12.29
Parameter
display of motor 2
0: Display based on the motor type; under this mode,
only parameters related to current motor type will be
displayed.
1: Display all; under this mode, all the parameters
0